HD-S series digital geophones
are designed with advanced technology, Its popular name:" Super Digital Seismic Geophone", they have high spurious frequency, perfect disturbance resistance, all parameters are controlled within ±2.5%,the distortion is lower than 0.1%.With good stability, high accuracy, plenteous signal, S Series are suitable to all kinds of accurate seismic exploration. All parts are made in precision, and the technique is mature and stable.
HD-10ES= SM-24 (I/O), HD-10XS=
GS-32CT(GEOSPACE)
Main Specifications(20℃) |
Parameter\Mode |
HD-10ES
(20℃) |
HD-10XS
(25℃) |
HD-40S
(20℃) |
Natural Frequency |
10±2.5% |
10±2.5% |
40±2.5% |
Coil Resistance |
375±2.5% |
395±2.5% |
755±2.5% |
Sensitivity |
28.8±2.5% |
27.5±2.5% |
36±2.5% |
Sensitivity With Shunt Resistor |
22.8±2.5%
(1339Ω) |
19.7±2.5%
(1000Ω) |
33±2.5%
(8200Ω) |
Damping |
0.25+5%/-0% |
0.316±2.5% |
0.60±2.5% |
Damping With Shunt Resistor |
0.60+5%/-0%
(1339Ω) |
0.70±2.5%
(1000Ω) |
0.631±2.5%
(8200Ω) |
Distortion |
≤0.1 |
≤0.1 |
≤0.1 |
Spurious frequency |
≥240 |
≥240 |
≥240 |
Max. Motion |
2 |
1.5 |
1 |
Moving Mass |
11 |
11.2 |
9.2 |
Dimensions |
25.4×34 |
25.4×34 |
26×34 |
Temperature Range |
-40--+100 |
-40--+100 |
-40--+100 |
Warranty Period |
3 |
3 |
3 |
Case Type |
|
|
HD-
B series digital geophones are mainly used in petroleum exploration. The series have wide frequency band. High spurious frequency and all parameters are controlled within ±5%. B Series have good stability, high accuracy, plenteous signal and its unique double coils structure considerably lowers the distortion, the coil can be within 360° freely which can effectively eliminate surface disturbance, so they have wonderful S/N, little phase displacement and high dynamic performance. With good temperature adaptability, they are suitable to all kinds of seismic exploration.
Main Specifications(20℃) |
Parameter\Mode |
HD-4.5B |
HD-10B |
HD-14B |
HD-28B |
HD-35B |
HD-40B |
HD-60A |
HD-100A |
Natural Frequency |
4.5±10% |
10±5% |
14±5% |
28±5% |
35±5% |
40±5% |
60±5% |
100±5% |
Coil Resistance |
375±5% |
375±5% |
375±5% |
390±5% |
560±5% |
548±5% |
940±5% |
1084±5% |
Sensitivity |
28.8±5% |
28.8±5% |
28.8±5% |
30.0±5% |
32.5±5% |
32.5±5% |
55±5% |
39±5% |
Sensitivity With Shunt Resistor |
|
22.8±5%
(1400Ω) |
18.2±5%
(640Ω) |
28.5±5%
(7500Ω) |
|
|
|
|
Damping |
0.60±5% |
0.271±5% |
0.20±5% |
0.60±5% |
0.60±5% |
0.615±5% |
0.65±5% |
0.42±5% |
Damping With Shunt Resistor |
|
0.60±5%
(1400Ω) |
0.60±5%
(640Ω) |
0.632±5%
(7500Ω) |
|
|
|
|
Distortion |
≤0.2 |
≤0.2 |
≤0.2 |
≤0.2 |
≤0.2 |
≤0.2 |
≤0.2 |
≤0.2 |
Max. Motion |
4 |
2 |
2 |
1.8 |
1.8 |
1.8 |
1 |
1 |
Moving Mass |
11.3 |
11.3 |
11.3 |
10.1 |
9.3 |
9.3 |
11.5 |
7.6 |
Dimensions |
25.4×36 |
25.4×32 |
25.4×32 |
25.4×32 |
25.4×32 |
25.4×32 |
27.5×34 |
27.5×34 |
Temperature Range |
-40--+70 |
-40--+70 |
-40--+70 |
-40--+70 |
-40--+70 |
-40--+70 |
-40--+70 |
-40--+70 |
Warranty Period |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
Case Type |
|
|
HD-D series digital geophones are mainly used in petroleum exploration. They have the same parameters with 20DX series and may exchange with 20DX series, but its unique double coils structure considerably lowers the distortion, and greatly more accurate, more wonderful dynamic performance. D series have small volume, light weight, stable technical capability, perfect accuracy, wonderful dynamic performance and long life.
Main Specifications(22℃) |
Parameter\Mode |
HD-8D |
HD-10D |
HD-14D |
HD-28D |
HD-40D |
Natural Frequency |
8±5% |
10±5% |
14±5% |
28±5% |
40±5% |
Coil Resistance |
395±5% |
395±5% |
395±5% |
395±5% |
575±5% |
Sensitivity |
28.0±5% |
28.0±5% |
28.0±5% |
39.0±5% |
42.0±5% |
Sensitivity With Shunt Resistor |
20.0±5%
(1000Ω) |
20.0±5%
(1000Ω) |
20.0±5%
(1000Ω) |
28.0±5%
(1000Ω) |
30.0±5%
(1000Ω) |
Damping |
0.38±5% |
0.30±5% |
0.22±5% |
0.27±5% |
0.42±5% |
Damping With Shunt Resistor |
0.70±5% |
0.70±5% |
0.50±5% |
0.56±5% |
0.57±5% |
Distortion |
< 0.2 |
< 0.2 |
< 0.2 |
< 0.2 |
< 0.2 |
Max. Motion |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
Moving Mass |
11 |
11 |
11 |
11 |
11 |
Dimensions |
25.4×32 |
25.4×32 |
25.4×32 |
25.4×32 |
25.4×32 |
Temperature Range |
-40--+70 |
-40--+70 |
-40--+70 |
-40--+70 |
-40--+70 |
Warranty Period |
3 |
3 |
3 |
3 |
3 |
Case Type |
|
|
HD-X series digital geophones are mainly used in petroleum exploration; the down_lead cable insures the stability of DC resistors. X series have small volume, light weight, stable technical capability, perfect accuracy, high spurious frequency, good disturbance resistance, wonderful S/N and dynamic performance, they are suitable to all kinds of seismic exploration. PS-10X can be exchanged with GS-20DX(GEOSPACE).
Main Specifications(20℃) |
Parameter\Mode |
HD-8X |
HD-10X |
HD-14X |
HD-28X |
HD-40X |
Natural Frequency |
8±10% |
10±5% |
14±5% |
28±5% |
40±5% |
Coil Resistance |
395±5% |
395±5% |
395±5% |
395±5% |
575±5% |
Sensitivity |
28.0±5% |
28.0±5% |
28.0±5% |
39.0±5% |
42.0±5% |
Sensitivity With Shunt Resistor |
20.0±5%
(1000Ω) |
20.0±5%
(1000Ω) |
20.0±5%
(1000Ω) |
23.0±5%
(1000Ω) |
30.0±5%
(1500Ω) |
Damping |
0.38±5% |
0.30±5% |
0.22±5% |
0.27±5% |
0.37±5% |
Damping With Shunt Resistor |
0.70±5%
(1000Ω) |
0.70±5%
(1000Ω) |
0.70±5%
(1000Ω) |
0.56±5%
(1000Ω) |
0.57±5%
(1500Ω) |
Distortion |
< 0.2 |
< 0.2 |
< 0.2 |
< 0.2 |
< 0.2 |
Max.Motion |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
Moving Mass |
11 |
11 |
11 |
11 |
8.2 |
Dimensions |
25.4×34 |
25.4×34 |
25.4×34 |
27×34 |
27×34 |
Temperature Range |
-40--+70 |
-40--+70 |
-40--+70 |
-40--+70 |
-40--+70 |
Warranty Period |
3 |
3 |
3 |
3 |
3 |
Case Type |
|
|